BACnet¶
Capabilities¶
Capability |
Support |
Comment |
---|---|---|
Connection state with BACnet device |
||
Reading value by subscription from BACnet device |
||
Reading value by polling from BACnet device |
||
Writing value to BACnet device |
See Writing values |
BACnet objects |
PRESENT_VALUE |
STATUS_FLAGS |
OUT_OF_SERVICE |
EVENT_STATE |
---|---|---|---|---|
Analog input read |
||||
Analog input write |
||||
Analog output read |
||||
Analog output write |
||||
Analog value read |
||||
Analog value write |
||||
Binary input read |
||||
Binary input write |
||||
Binary output read |
||||
Binary output write |
||||
Binary value read |
||||
Binary value write |
||||
Multi-state value read |
||||
Multi-state value write |
||||
Signed integer value read |
||||
Signed integer value write |
||||
Unsigned integer value read |
||||
Unsigned integer value write |
PRESENT_VALUE |
DECIMAL |
INTEGER |
TEXT |
BOOLEAN |
---|---|---|---|---|
Analog input read |
||||
Analog input write |
||||
Analog output read |
||||
Analog output write |
||||
Analog value read |
||||
Analog value write |
||||
Binary input read |
||||
Binary input write |
||||
Binary output read |
||||
Binary output write |
||||
Binary value read |
||||
Binary value write |
||||
Multi-state value read |
||||
Multi-state value write |
Examples¶
Read a BACnet value by subscription Read a BACnet value by polling Write a BACnet value
Concept¶
OnSphere let the user connect to a BACnet device to write or read properties.
Warning
In cases where a BACnet router (BBDM) is not available, the osp-bacnet connector should be given access to the network of the bacnet device. This can only be achieved using a remote connector and starting the osp-bacnet container with the --network=host
option. You can also link the bridge network and add that network to your module. Be careful the outside_access
network is an overlay
which does not have the same properties as a true bridge
network. Refer to the overlay documentation and bridge documentation.
networks:
[...]
bridge:
external:
name: bridge
${{service-name}}:
image: ${{image-repository}}osp-bacnet${{image-version}}
networks:
- "back"
- "bridge"
[...]
Warning
For the moment only connection on port 47808/UDP is supported.
Note
Converting a BINARY_* BACnet type to a textual value will result as active and inactive states.
BACnet device connection monitoring¶
The connection state between the BACnet module and a device can be read as a BOOLEAN value from the BACnet device in the OnSphere hierarchy (i.e. root.BACnet.device_123456 for example).
Warning
This value will only be updated once you try to read or write on the device.
Example¶
Read a BACnet value by subscription Read a BACnet value by polling Write a BACnet value
Reading values with subscription¶
Concept¶
A subscription is renewed at the value strategy frequency (defaults to 30 seconds) and has twice the lifetime, meaning the module will take at most strategyFrequency to detect an error reading the value and report it.
Usage¶
SINGLE_SUBSCRIPTION : Renewable subscription monitoring changes of the presentValue property of the BACnet object in real time.
OBJECT_SUBSCRIPTION : Renewable subscription monitoring changes of any parameters in a BACnet objet in real time. However, only changes of the PRESENT_VALUE property are reported by the module.
Example¶
Reading values with polling¶
Concept¶
MULTIPLE_POLLING : Values sharing this strategy on the same device are polled in a single read request and are read in a single response. This can lower the network overhead of the polling strategy.
SINGLE_POLLING : Each value is polled in a dedicated read request and read in a dedicated response.
Values are polled at the value strategy frequency (defaults to 5 seconds), meaning the module will take at most strategyFrequency to detect an error reading the value and report it.
Example¶
Writing values¶
BACnet outputs allow to write :
The present value of binary/analog outputs/values and multi state values
The out of service property of a BACnet object