output.opc-ua¶
Opc Ua Output File¶
oneOf |
OpcUa Write Output |
OpcUa Method Output |
|
OpcUa Write Output¶
type |
object |
||
properties |
|||
|
type |
string |
|
enum |
Write |
||
default |
Write |
||
|
The id of the template to use for this file |
||
type |
string |
||
|
The variables and their values to be replaced from the template |
||
type |
object |
||
additionalProperties |
|||
|
The variables files to use to replace the variables. The first file of the list will take precedence over the following one. Template variables take precedence over the contents of the files. |
||
type |
array |
||
items |
type |
string |
|
|
If the value is set to true, manual editing of this file should be avoided, as the composer will override the value in the next generation. |
||
type |
boolean |
||
|
The OPC UA device device.opc-ua ↗️ that this owner will use to get the value. For example, |
||
type |
string |
||
|
Specifies the namespace the node belongs to. Namespaces help avoid conflicts between different sources of information and manage nodes from different standards or vendors. For example, in ns=2;s=TemperatureSensor, 2 is the index namespace. Knowing this you would put |
||
type |
integer |
||
|
The node identifier is the part of the NodeId that uniquely identifies a node within a given namespace. The identifier can be a numeric value, a string, a GUID, or an opaque byte string. For the moment only strings are handled. For example if a NodeId use the following path ns=2;s=TemperatureSensor. Knowing this you would put |
||
type |
string |
||
additionalProperties |
False |
OpcUa Method Output¶
type |
object |
||
properties |
|||
|
type |
string |
|
enum |
Method |
||
default |
Method |
||
|
The id of the template to use for this file |
||
type |
string |
||
|
The variables and their values to be replaced from the template |
||
type |
object |
||
additionalProperties |
|||
|
The variables files to use to replace the variables. The first file of the list will take precedence over the following one. Template variables take precedence over the contents of the files. |
||
type |
array |
||
items |
type |
string |
|
|
If the value is set to true, manual editing of this file should be avoided, as the composer will override the value in the next generation. |
||
type |
boolean |
||
|
The OPC UA device device.opc-ua ↗️ that this owner will use to get the value. For example, |
||
type |
string |
||
|
Specifies the namespace the node belongs to. Namespaces help avoid conflicts between different sources of information and manage nodes from different standards or vendors. For example, in ns=2;s=TemperatureSensor, 2 is the index namespace. Knowing this you would put |
||
type |
integer |
||
|
The method identifier is the NodeId of the method node. It uniquely identifies the method within the address space of the OPC UA server. For example if a method use the following id ns=2;s=TemperatureSensor, it can be located in the object ns=2;s=ServerA. Knowing this you would put |
||
type |
string |
||
|
The method object identifier is the NodeId of the object node that contains the method. This is the node representing the object or component to which the method belongs. For example if a method use the following id ns=2;s=TemperatureSensor, and can be located in the object ns=2;s=ServerA. Knowing this you would put |
||
type |
string |
||
additionalProperties |
False |